Table 8.5 BATTERY CHARGING TEMPERATURE
COMPENSATION PER CELL
ELECTROLYTE
TEMPERATURE
(°F)
ELECTROLYTE
TEMPERATURE
(°C)
DEVIATION IN
CHARGE
VOLTAGE (Vdc)
+/- RANGE
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
-17.8
-12.2
-6.7
-1.1
4.4
10.0
15.6
21.1
26.7
32.2
37.8
43.3
48.9
54.4
60.0
65.6
71.1
+
+
+
+
+
+
+
+
-
-
-
-
-
-
-
-
.224 - .264
.196 - .231
.168 - .198
.140 - .165
.112 - .132
.084 - .099
.056 - .066
.028 - .033
0.000
.028 - .033
.056 - .066
.084 - .099
.112 - .132
.140 - .165
.168 - .198
.196 - .231
.224 - .264
Notes:
1) Deviation is 2.80 to 3.30 mV/°F/cell
Table 8.6 MODULATION TABLE FOR A
TEMPERATURE COMPENSATED BATTERY
CHARGER (TYPE 1)
Row
VMOD
(Vdc) Mod
Vo
(Vdc)
1
2
3
4
5
0.000
0.513
0.692
1.205
9999
0.183
0.183
-0.183
-0.183
0.000
16.10
16.10
-13.18
-13.18
0
Note: Set the program voltage to 14.64V.