Query Syntax: MEASure:VOLTage[:DC]? <>
Examples: MEAS:VOLT?
MEASURE:VOLTAGE:DC?
Returned Parameters: <NR2>
4.3.2.2 MEAS:CURR?
Query Syntax: MEASure:CURRent[:DC]? <>
Examples: MEAS:CURR?
MEASURE:CURRENT:DC?
Returned Parameters: <NR2>
4.3.3 System Subsystem
The System subsystem returns information about the state of the power supply.
4.3.3.1 SYST:VERS?
This query returns the firmware and hardware version of the power supply. The returned value
has the form Firmware Rev. X.X, Hardware Rev. X.X.
Query Syntax: SYSTem:VERSion? <>
Examples: SYST:VERS?
SYSTEM:VERSION?
Returned Parameters: <Firmware Rev. XX.Y, Hardware Rev. XX.Y>
Related Commands: None
4.3.3.2 SYST:ERR?
The SYST:ERR? query returns the error messages that have occurred in the system. The format
of the return string is an error number followed by a corresponding error message string. The
errors are stored in a FIFO (first-in, first-out) buffer. As the errors are read, they are removed
from the queue. When all errors have been read, the query returns 0,”NO ERROR.” If more
errors have accumulated than the queue can hold, the last error in the queue will be -350,”Queue
Overflow” (see Table 4.8, Error Messages, for other error codes).
Query Syntax: SYSTem:ERRor? <>