Vista de página 46
(b)
VO1REM-
VO1REM+
VS-
VS+
(a)
1
2
JS2
LOAD
VO-
VO+
MULTIPLEXER
MULTIPLEXER
VO+
VO-
LOAD
JS2
2
1
VS+
VS-
VO1REM+
VO1REM-
Figure 3.12 (a) Local and (b) remote sensing
3.4 External Programming
XR Series supplies allow voltage, current, voltage trip, and current trip to be programmed from a
remote location. Programming can be accomplished either by resistive, voltage, or current
programming circuits.
Figure 3.13 illustrates the three alternatives for programming the voltage set point. The method
applies equally to programming set point current, over voltage trip, and over current trip.